Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
STRUCTURAL | ABKW | OVERALL HEIGHT1 000 INCHES NOMINAL |
STRUCTURAL | ABRY | LENGTH10 000 FEET MINIMUM AND 12 000 FEET MAXIMUM |
STRUCTURAL | AJJP | LEG THICKNESS0 078 INCHES NOMINAL |
STRUCTURAL | BPXJ | FILLET RADIUS WHERE TOP LEFT FLANGE JOINS WEB FLANGELEG0 125 INCHES NOMINAL |
STRUCTURAL | BPXL | FILLET RADIUS WHERE TOP RIGHT FLANGE JOINS WEB FLANGELEG0 125 INCHES NOMINAL |
STRUCTURAL | BQJG | TOP FLANGE WIDTH3 260 INCHES NOMINAL |
STRUCTURAL | BRFD | WEIGHT PER UNIT MEASURE0 600 POUNDS PER LINEAR FOOT |
STRUCTURAL | CNBD | FIRST TIP INNER RADIUS0 031 INCHES NOMINAL |
STRUCTURAL | CNQJ | SECOND TIP RELATIONSHIP TO FIRST TIPIDENTICAL |
STRUCTURAL | CRZC | RIGHT TOP INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | HEAT | HEAT TREATMENTT-6 SOLUTION HEAT TREATED AND ARTIFICALLY AGED |
STRUCTURAL | ZZZT | NONDEFINITIVE SPECSTD DATAT6 TEMPER |
STRUCTURAL | AARN | FABRICATION METHODEXTRUDED |
STRUCTURAL | ADXR | LEFT SIDE TOP FLANGE THICKNESS0 125 INCHES NOMINAL |
STRUCTURAL | ADXS | RIGHT SIDE TOP FLANGE THICKNESS0 125 INCHES NOMINAL |
STRUCTURAL | AGTA | BASIC SHAPE STYLET SHAPE |
STRUCTURAL | BPXD | LEFT SIDE TOP FLANGE DISTANCE TO CENTER OF BOTH FLANGES1 630 INCHES NOMINAL |
STRUCTURAL | BPXG | RIGHT SIDE TOP FLANGE DISTANCE TO CENTER OF BOTH FLANGES1 630 INCHES NOMINAL |
STRUCTURAL | CMZY | FIRST TIP STYLESQUARE W INNER AND OUTER CORNER RADII |
STRUCTURAL | CNBB | THIRD TIP RADIUS0 062 INCHES NOMINAL |
STRUCTURAL | CNBJ | FIRST TIP OUTER RADIUS0 031 INCHES NOMINAL |
STRUCTURAL | CNPB | THIRD TIP DIAMETER0 188 INCHES NOMINAL |
STRUCTURAL | CNQL | THIRD TIP RELATIONSHIP TO PRECEDING TIPSNOT IDENTICAL |
STRUCTURAL | CNQM | THIRD TIP STYLELEFT BULBOUS |
STRUCTURAL | CSMZ | LEFT TOP INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | MATT | MATERIALALUMINUM ALLOYQQ-A-20011ALLOY 7075 |
STRUCTURAL | ZZZK | SPECIFICATIONSTANDARD DATA81348-QQ-A-20011 GOVERNMENT SPECIFICATION |
912-0005-01 | 912-0004-00 | 912-0008 | 912-0006 |
912-0007 | 912-0008-01 | 912-0004 | 912-0006-01 |
912-0010-00 | 912-0009 | 912-0004-01 | 912 00 008 |
912-0010-02 | 912-0011 | 912-00-008 | 912-0005 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |