NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-291-2656 Item Description: Power Supply | 6130 | 012912656 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 5 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
49731-01 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
APPA | OUTPUT VOLTAGE RATING | -19.0 DC VOLTS MINIMUM 4TH POWER OUTPUT AND -21.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 20.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.7 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.1/+50.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | REMOTE ERROR SENSING CAPABILITY AND OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR AND OVER TEMPERATURE PROTECTION AND REVERSE VOLTAGE PROTECTION AND CIRCUIT BREAKER AND FUSE AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND |
CWGH | OUTPUT CURRENT RATING | -18.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | -18.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 18.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 220.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT AND THREADED STUD SINGLE POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | AIR COOLED |
CWWY | POWER SUPPLY EFFICIENCY LINE | 70.0 |
ABHP | OVERALL LENGTH | 28.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AN-ALQ172 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 180.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 132.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -11.4 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -12.6 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
497-0004 | 497-0012 | 497-0021 | 497-0021 |
497-003 | 497-003 | 497-0039 | 497-004-002 |
497-004-002 | 497-0047 | 497-0047 | 497-007 |
497-007 | 497-0080 | 497 0098 | 497-0098 |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote