Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6105-00-851-8735 Item Description: Motor Control | 6105 | 008518735 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
008518735-01173 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJT | OVERALL HEIGHT | 1.750 INCHES |
AAJU | III OVERALL LENGTH | 1.953 INCHES |
AAJV | OVERALL WIDTH | 1.750 INCHES |
ABSA | SPLINE QUANTITY | 18 SINGLE END |
ABWV | SHAFT DIAMETER | 0.2083 INCHES NOMINAL SINGLE END |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
AXFH | SPLINE LENGTH | 0.1100 INCHES NOMINAL SINGLE END |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
BFMF | COOLING METHOD | NONVENTILATED |
BFMJ | CONTROL FIELD CURRENT RATING IN AMPS | 0.077 |
BFMK | CONTROL FIELD IMPEDANCE RATING IN OHMS | 8700.0 |
BFML | CONTROL FIELD WINDING TYPE | SINGLE WINDING W/CENTER TAP |
BKPB | CURRENT RATING METHOD | LOAD |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
CWFX | ROTOR SPEED RATING IN RPM | 5000.0 SINGLE NO LOAD |
CWGL | CURRENT RATING IN AMPS | 0.0187 SINGLE INPUT |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 115.0 LINE TO NEUTRAL SINGLE INPUT |
CWHZ | SHAFT END CHARACTERISTIC | A14 SINGLE STYLE SINGLE END |
FREQ | FREQUENCY IN HERTZ | 400.0 INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
AAUH | SPLINE MINOR DIAMETER | 0.1875 INCHES NOMINAL SINGLE END |
ACDC | CURRENT TYPE | AC INPUT |
AXGY | MOUNTING METHOD | CLAMP RING |
BKPH | TORQUE RATING AND TYPE | 2.15 INCH-OUNCES STALLED |
BKPS | CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 280.0 AC |
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.187 INCHES SINGLE END |
CWDY | TEMP RATING | 60.0 AMBIENT DEG CELSIUS AND -55.0 OPERATING DEG CELSIUS AND 90.0 OPERATING DEG CELSIUS |
FAAZ | PHASE | SINGLE INPUT |
008-00050-0000 | 008-00063-8 | 008-0002 | 008-00073-2 |
008-00001-0001 | 008-0005 | 008-00064-0000 | 008-00019-02 |
008-00073-2 | 008 0005 002 | 008-0008-51A | 008-0001-01 |
008-00062-5 | 008-0005-000 | 008-0005 | 008-0000144 |